Welding Cable Structure
*Any other Color on specific request can also be supplied
Welding Cable Technical Data
Welding Cable features
Welding Cable Application
Welding Cable is for use on connections from electrode holders and clamps to arc welders, bus welding box or transformers. Welding cable is for applications up to 600 volts and temperatures from -30°C to +90°C.
Standard length cable packing:
Coils 100, 200, 300 and 500 m. in wooden reels
Technical Information
| Cross Sectional Area | Copper Construction | Inner Dia. | Outer Dia Appx. | Max. Conductor Resistance at 20˚C | Max. Current (Amb. Temp of 40˚C) |
|---|---|---|---|---|---|
| AWG | Nos. / Dia. mm | mm | mm | Ω/km | AMPS |
| 6 | 273 / 0.254 | 8.00 | 10.70 | 1.39 | 115 |
| 4 | 427 / 0.254 | 9.50 | 12.10 | 0.873 | 150 |
| 2 | 651 / 0.254 | 11.00 | 14.20 | 0.554 | 205 |
| 1 | 817 / 0.254 | 11.70 | 15.40 | 0.44 | 240 |
| 1/0 | 1045 / 0.254 | 12.30 | 16.30 | 0.349 | 285 |
| 2/0 | 1330 / 0.254 | 14.40 | 18.70 | 0.276 | 325 |
| 3/0 | 1672 / 0.254 | 16.60 | 20.80 | 0.221 | 380 |
| 4/0 | 2146 / 0.254 | 18.20 | 23.00 | 0.175 | 440 |
| 250MCM | 2508 / 0.254 | 21.10 | 27.60 | 0.149 | 495 |
| 350MCM | 3496 / 0.254 | 20.80 | 30.80 | 0.106 | 680 |
| 500MCM | 5013 / 0.254 | 26.80 | 34.00 | 0.0743 | 720 |
length in feet for total circuit for secondary voltages only – do not use this table for 600 Volt in-line applications
| AMPS | 100' | 150' | 200' | 250' | 300' | 350' | 400' |
|---|---|---|---|---|---|---|---|
| 100 | 4 | 4 | 2 | 2 | 1 | 1/0 | 1/0 |
| 150 | 4 | 2 | 1 | 1/0 | 2/0 | 3/0 | 3/0 |
| 200 | 2 | 1 | 1/0 | 2/0 | 3/0 | 4/0 | 4/0 |
| 250 | 1 | 1/0 | 2/0 | 3/0 | 4/0 | ||
| 300 | 1/0 | 2/0 | 3/0 | 4/0 | |||
| 350 | 1/0 | 3/0 | 4/0 | ||||
| 400 | 2/0 | 3/0 | |||||
| 450 | 2/0 | 4/0 | |||||
| 500 | 3/0 | 4/0 | |||||
| 550 | 3/0 | 4/0 | |||||
| 600 | 4/0 |
Required Cable Sizes Shown In Awg Numbers
The total circuit length includes both welding and ground leads (based on 4-volt drop) 60% duty cycle.