HO5Z-K 300/500 V HO7Z-K 450/750 V

Cable Structure

Conductor Fine Stranded Copper (Class 5 - Flexible Plain Copper) to VDE 0295 IEC 60228
Insulation Cross-linked polymer : Polymer compound, flame retardant, low smoke halogen free EI5 LSZH
Colour Green/Yellow, Blue, Black, Brown, Grey, Orange, Pink, Red, Violet, White, Green, Yellow or other colours
Flame propagation Zero halogen IEC 60754-2, Flame retardant test as per IEC 60332-1

Technical Data

Operating Temp -30°C to +90°C
Nominal voltage HO5Z-K : 300/500 V
HO7Z-K : 450/750 V
Test voltage HO5Z-K : 2500 V
HO7Z-K : 2500 V
Insulation resistance Min. 10 MΩ x km
Min. bending radius 4 x cable diameter

Cable features

  • Special heat resistant thermosetting insulation
  • High current carrying capacity
  • LSZH and Ozone resistant insulation material
  • Better fire retardant properties
  • Non corrosive & non toxic
  • Long flex life
  • Excellent resistant to moisture, abrasion, grace, oil
  • Excellent mechanical & electrical properties
  • Harmonized acc. to European standards
  • Tested by SGS, EIL, RITES, NPC, INTERTEK

Application

HO5Z-K, H07Z-K
Fixed installation in conduits and under plaster, for appliance wiring and distribution stations For wiring of lamps, devices, switchgear cabinets and distribution boxes

Standard length cable packing:
Coils 100 and 200 m in carton boxes, reels

H05Z-K (300/500 V)

Size in mm2 Nos/ dia. (Nom.) Insulation Thickness in mm ( nom.) Outer Dia in mm (Appx.) Max. C.R in ohm/km Copper
0.5 16/0.200 0.60 2.10 39.00
0.75 24/0.200 0.60 2.20 26.00
1 32/0.200 0.60 2.70 19.50
  • All are class 5 flexible conductor
  • Insulation grade is TI1

Note:

The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360 or UL83

H07Z-K (450/750 V)

Size in mm2 Nos/ dia. (Nom.) Insulation Thickness in mm ( nom.) Outer Dia in mm (Appx.) Max. C.R in ohm/km Copper
1.5 30/0.250 0.70 3.25 13.3
2.5 50/0.250 0.80 3.80 7.98
4 56/0.300 0.80 4.50 4.95
6 84/0.300 0.80 5.25 3.30
10 140/0.300 1.00 6.50 1.91
16 224/0.300 1.00 8.00 1.21
25 350/0.300 1.20 10.10 0.780
35 490/0.300 1.20 11.30 0.554
50 703/0.300 1.40 13.50 0.386
70 988/0.300 1.40 15.30 0.272
95 1349/0.300 1.60 18.00 0.206
120 608/0.500 1.60 19.80 0.161
150 760/0.500 1.80 22.30 0.129
185 943/0.500 2.00 23.90 0.106
240 1225/0.500 2.20 26.80 0.0801
  • All are class 5 flexible conductor