PVC Armoured Cables

Cable Structure

generally conforms to IS 1554-1, IEC 60502-1, BS 6346

Conductor Material - Copper According to VDE 0295 class 1 or 2 (IEC 60228,IS 8130)
Insulation PVC Type A of IS:5831
Inner Sheath PVC
Armouring Single layer of GS round wire or Flat Strips
Outer Sheath PVC TYPE ST-1 OF IS : 5831

TECHNICAL DATA

Operating Temp. -20°c to max.+90°C
Nominal voltage 1100 V
Test voltage 3000 V
Insulation resistance Min. 10 MΩ x km
Min. bending radius Single core :15 X Overall diameter
   Multi core :12 X Overall diameter
Flame propagation Flame retardant test as per IEC 60332-1

Application

PVC Armoured Cables
Power cables for energy supply are installed outdoors, in underground, in water, indoors, in cable ducts, power stations, for industry and distribution boards as well as in subscriber networks, where mechanical damages are no

Standard length cable packing:
Coils 100, 200, 300, 500, 1000 m. in wooden reels

Color Coding: AS IS 1554 ( Indian Standard )

Single core 2 Core 3 Core 4 Core 5 Core
Red or Black Red, Black Red, Yellow, Blue Red, Yellow, Blue, Black Red, Yellow, Blue, Black, Grey

Color coding: AS IEC 60502 Part-1, B.S. 6346

Single core 2 Core 3 Core 4 Core 5 Core
Black or Yellow/Green Blue and Brown or Yellow-Green and Black Brown, Black, Grey or Yellow/Green, Blue, Brown Blue, Brown, Black, Grey or Yellow/Green, Brown, Black, Grey Blue, Brown, Black, Grey, Black or Yellow/Green, Blue, Brown, Black, Grey

Technical DataTable

Yogicab 1.1 kV 3 CORE COPPER CONDUCTOR PVC INSULATED , INNER SHEATHED ARMOURED PVC SHEATHED CABLES (IS : 1554 PART 1 )
CABLE CODE : YWY/YFY
SIZE (MM2) INSULATION PVC THICKNESS IN MM (NOM.) INNER SHEATH PVC THICKNESS IN MM (MIN.) ARMOUR SIZE IN MM (G.I) OUTER SHEATH PVC THICKNESS IN MM (MIN.) APPROX OUTER SHEATH O/D IN MM APPROX WEIGHT OF CABLE (KGS./KM) MAX.DC CONDUCTOR RESISTANCE at 20° C (Ohm/Km) Current Ratings (Amp.)
MAIN CORE HALF CORE W H Direct
In
Ground
In Air
3.5C X 250.900.700.304.00.801.4022.7014240.727120125
3.5C X 350.900.700.304.00.801.4024.5017480.524145155
3.5C X 501.000.900.304.00.801.5628.5023910.387170190
3.5C X 701.100.900.404.00.801.5032.1531080.268210235
3.5C X 951.101.000.404.00.801.5636.1040820.193250290
3.5C X 1201.201.100.504.00.801.7240.5051350.153285330
3.5C X 1501.401.100.504.00.801.8844.1061370.124315375
3.5C X 1851.601.100.604.00.802.0449.1575420.0991355435
3.5C X 2401.701.200.704.00.802.2054.6094330.0754410510
3.5C X 3001.801.400.804.00.802.3660.40115670.0601460590
3.5C X 4002.001.600.804.00.802.5268.10149830.0470520670
3.5C X 5002.201.701.004.00.802.8476.10186990.0366580750

Technical DataTable

Yogicab 1.1 kV 3 CORE COPPER CONDUCTOR PVC INSULATED , INNER SHEATHED ARMOURED PVC SHEATHED CABLES (IS : 1554 PART 1 )
CABLE CODE : YWY/YFY
SIZE (MM2) INSULATION PVC THICKNESS IN MM (NOM.) INNER SHEATH PVC THICKNESS IN MM (MIN.) ARMOUR SIZE IN MM (G.I) OUTER SHEATH PVC THICKNESS IN MM (MIN.) APPROX OUTER SHEATH O/D IN MM APPROX WEIGHT OF CABLE (KGS./KM) MAX.DC CONDUCTOR RESISTANCE at 20° C (Ohm/Km) Current Ratings (Amp.)
W H Direct
In
Ground
In Air
3 C X 1.50.800.301.401.2413.2037712.102117
3 C X 2.50.900.301.401.2414.404547.412724
3 C X 41.000.301.401.2416.506034.613630
3 C X 61.000.301.401.4017.907203.084539
3 C X 101.000.304.00.801.4018.858281.836052
3 C X 161.000.304.00.801.4021.0010921.157766
3 C X 251.200.304.00.801.4021.6012700.7279990
3 C X 351.200.304.00.801.4023.5016020.524120110
3 C X 501.400.304.00.801.4026.8521410.387145135
3 C X 701.400.404.00.801.5629.9527620.268175165
3 C X 951.600.404.00.801.5633.9036360.193210200
3 C X 1201.600.404.00.801.5636.5544380.153240230
3 C X 1501.800.504.00.801.7240.6054480.124270265
3 C X 1852.000.504.00.801.8844.5065550.0991300305
3 C X 2402.200.604.00.802.0449.6082200.0754345355
3 C X 3002.400.604.00.802.2054.70101120.0601385400
3 C X 4002.600.704.00.802.3661.60132080.0470425455

Technical DataTable

Yogicab 1.1 kV 4 CORE COPPER CONDUCTOR PVC INSULATED , INNER SHEATHED ARMOURED PVC SHEATHED CABLES (IS : 1554 PART 1 )
CABLE CODE : YWY/YFY
SIZE (MM2) INSULATION PVC THICKNESS IN MM (NOM.) INNER SHEATH PVC THICKNESS IN MM (MIN.) ARMOUR SIZE IN MM (G.I) OUTER SHEATH PVC THICKNESS IN MM (MIN.) APPROX OUTER SHEATH O/D IN MM APPROX WEIGHT OF CABLE (KGS./KM) MAX.DC CONDUCTOR RESISTANCE at 20° C (Ohm/Km) Current Ratings (Amp.)
W H Direct
In
Ground
In Air
4 C X 1.50.800.301.401.2414.1044612.102117
4 C X 2.50.900.301.401.2415.405447.412724
4 C X 41.000.301.401.4018.157504.613630
4 C X 61.000.301.401.4018.207783.084539
4 C X 101.000.304.00.801.4020.5510411.836052
4 C X 161.000.304.00.801.4023.2013981.157766
4 C X 251.200.304.00.801.4025.6516900.7279990
4 C X 351.200.304.00.801.5628.5521680.524120110
4 C X 501.400.404.00.801.5632.7029040.387145135
4 C X 701.400.404.00.801.5636.1536980.268175165
4 C X 951.600.404.00.801.7241.4549130.193210200
4 C X 1201.600.504.00.801.8845.2060300.153240230
4 C X 1501.800.504.00.802.0449.9573700.124270265
4 C X 1852.000.604.00.802.2055.1089160.0991300305
4 C X 2402.200.604.00.802.3661.20111370.0754345355
4 C X 3002.400.704.00.802.5267.70137150.0601385400
4 C X 4002.600.704.00.802.8476.75179610.0470425455

call