RUBBER 3 & 4 CORE ROUND CABLES HO7RN-F

CONSTRUCTION

Conductor Finely stranded bare flexible copper conductor
Insulation PVC
Sheath PVC
Core Colours 3core : 3core : Red, Yellow, Black,
   4core: Red, Yellow, Black, Green

APPLICATIONS

For continuous use in deep well to supply power to submersible motors for the depth upto 500 mtrs.

SPECIAL FEATURES

  • Cable is in accordance with UL specification for 75 degree C type TW cable.
  • Generally conforming to: UL 83, IEC 60227, BS 6500, ISI 694
  • Excellent resistant to moisture, abrasion, grease and oil
  • Excellent resistance to oils, acids, chemicals and ozone.

3 CORE ROUND CABLE FOR SUBMERSIBLE PUMPS (450/750 VOLTS)

Conductor Rubber
Insulation
Rubber
Sheath
Approx.
Overall Dia.
Conductor
Resistance
at 20°C (Max)
Nominal
Size in
Nos. &
Dia of Wire
Nominal
Thickness
Nominal
Thickness
Sq. mm. Nos./mm mm mm mm ohms/km
1.50 22/0.30 0.80 1.60 10.20 12.10
2.50 36/0.30 0.90 1.80 11.90 7.41
4.00 56/0.30 1.00 1.90 13.50 4.95
6.00 84/0.30 1.00 2.10 15.60 3.30
10.00 140/0.30 1.20 3.30 20.60 1.91
16.00 226/0.30 1.20 3.50 24.20 1.21
25.00 354/0.30 1.40 3.80 29.10 0.780
35.00 490/0.30 1.40 4.10 32.10 0.554
50.00 703/0.30 1.60 4.50 38.10 0.386
70.00 988/0.30 1.60 4.80 42.30 0.272
95.00 1349/0.30 1.80 5.30 49.10 0.206

4 CORE ROUND CABLE FOR SUBMERSIBLE PUMPS (450/750 VOLTS)

Conductor Rubber
Insulation
Rubber
Sheath
Approx.
Overall Dia.
Conductor
Resistance
at 20°C (Max)
Nominal
Size in
Nos. &
Dia of Wire
Nominal
Thickness
Nominal
Thickness
Sq. mm. Nos./mm mm mm mm ohms/km
1.50 22/0.30 0.80 1.70 11.20 12.10
2.50 36/0.30 0.90 1.90 13.00 7.41
4.00 56/0.30 1.00 2.00 14.90 4.95
6.00 84/0.30 1.00 2.30 17.50 3.30
10.00 140/0.30 1.20 3.40 22.60 1.91
16.00 224/0.30 1.20 3.60 27.10 1.21
25.00 350/0.30 1.40 4.10 32.70 0.780
35.00 490/0.30 1.40 4.40 36.20 0.554
50.00 703/0.30 1.60 4.80 42.30 0.386
70.00 988/0.30 1.60 5.20 48.20 0.272
95.00 1349/0.30 1.80 5.90 55.60 0.206

Note:

  • The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360
  • In view of continuous improvements in our design and process, specifications given here in are subject change without notice.