PVC 3 & 4 CORE FLAT CABLES- AWG

CONSTRUCTION

Conductor Finely stranded bare flexible copper conductor
Insulation PVC
Sheath PVC
Core Colours 3core : Red, Yellow, Black,
   4core: Red, Yellow, Black, Green

APPLICATIONS

For continuous use in deep well to supply power to submersible motors for the depth upto 500 mtrs.

SPECIAL FEATURES

  • Cable is in accordance with UL specification for 75 degree C type TW cable.
  • Generally conforming to: UL 83, IEC 60227, BS 6500, ISI 694
  • Excellent resistant to moisture, abrasion, grease and oil
  • Excellent resistance to oils, acids, chemicals and ozone.

PVC 3 Core Flat Submersible Pump Cables(Without Ground)

Conductor
Size (AWG)
Nos and Dia.
of wire (Nos. x mm)
Core Dia.
(mm)
Nominal Sheath
Thickness (mm)
Cable Overall
Dimension (mm)
14 41 x 0.254 3.60 1.15 13.30 x 6.20
12 65 x 0.254 4.30 1.15 15.60 x 7.00
10 105 x 0.254 5.10 1.15 17.70 x 7.40
8 168 x 0.254 6.30 1.40 22.30 x 9.30
6 226 x 0.254 7.60 1.40 26.30 x 10.80
4 420 x 0.254 9.90 2.00 32.30 x 13.10
2 665 x 0.254 11.10 2.00 35.90 x 14.30
1 817 x 0.254 13.60 2.20 45.50 x 18.30
1/0 1045 x 0.254 13.60 2.20 45.50 x 18.30
2/0 1330 x 0.254 15.60 2.20 51.00 x 21.00
3/0 1672 x 0.254 18.00 2.40 61.00 x 23.50
4/0 2116 x 0.254 19.80 2.65 65.00 x 25.20
250 MCM 2503 x 0.254 20.60 2.80 68.00 x 28.00

PVC 4 Core Flat Submersible Pump Cables (With Ground)

Conductor
Size (AWG)
Nos and Dia.
of wire (Nos. x mm)
Ground Conductor
Size (AWG)
Core Dia.
(mm)
Nominal Sheath
Thickness (mm)
Cable Overall
Dimension (mm)
14 41 x 0.254 14 3.85 1.15 18.00 x 6.50
12 65 x 0.254 12 4.50 1.15 21.00 x 7.60
10 105 x 0.254 10 5.30 1.15 24.30 x 7.90
8 168 x 0.254 10 6.50 1.40 29.70 x 9.90
6 266 x 0.254 8 8.00 2.00 36.00 x 11.80
4 420 x 0.254 8 10.10 2.00 45.10 x 14.70
2 665 x 0.254 6 11.30 2.20 50.10 x 16.20
1 817 x 0.254 6 13.60 2.20 58.10 x 19.00
1/0 1045 x 0.254 6 13.60 2.20 58.10 x 19.00
2/0 1330 x 0.254 4 15.60 2.20 66.50 x 21.50
3/0 1672 x 0.254 2 18.00 2.65 77.30 x 23.50
4/0 2116 x 0.254 2 19.80 3.85 87.00 x 27.80